Part of HIS connect® Solar Wiring System

HIKRA®Solar cable

HIKRA® stands for more. More quality by testing which goes above and beyond the current
product norms. More safety thanks to improved reaction to fire. More service thanks to
varied designs and greater availability in our warehouses on three continents.
HIKRA®: the comprehensive cabling solution for international successful EPC and
Installation companies which expect more from their suppliers.

#

HIKRA® SOL (H1Z2Z2-K)

#
Your benefits:
  • Certification: EN50618; NEW: IEC62930
  • Nominal voltage 1,5kV DC (up to 1,8kV DC max. operating voltage)
  • Maximum permitted operating voltage: 1,8kV DC
    (2,0 kV DC internal examination)
  • Thanks to high-quality materials ready for direct burial (acc. UL 44 cl. 5.4 & UL2566 cl. 6.4.4.2)
  • Electron-beam cross-linked special compound; XLPO/XLPO
  • CPR-classification of burning behavior acc. to 305/2011/EU: B2ca, s1a, d0, a1
  • Halogen free, flame retardant, UV and ozone resistant
  • To aid installation: We ship this cable with meter-marking.
  • Colour coding to seperate polarities
  • Availabe in 100m coils, 500 m drums or in another kind upon request
Technical data
Nominal voltage  1,5kV DC and 1,0kV AC (max. operating voltage 1,8kV DC)
Maximum permitted operating voltage 1,8kV DC (2,0 kV DC internal examination)
Test voltage 6,5kV AC / 15kV DC (5 minutes water bath, 20±5°C)
Strand construction  Tin-plated copper (electrolytic copper), fine wire acc. IEC 60228 Class 5
Short-circuit-temperature  250° C/5s
UV stability Tensile strength and ultimate-elongation after 720 h (360 cycles) ≥ 70% of initial values; EN 50289-4-17 acc. Method A; EN ISO 4892-1 (2000) and EN ISO 4892-2 (2006) 
Insulation resistance Insulation resistance in water bath, each 2h at +90°C and 2h at 20°C (Limit values acc. EN 50618 Table 1)
Resistance against acid and alkaline solution 168h at 23°C in N-Oxal acid and N-Sodium hydroxide (EN 60811-404); ammoniac-resistant
Behaviour in case of fire  Flame-retardant acc. EN 60332-1-2 Annex A, low smoke emission (EN 61034,-2) 
Halogen-free  EN 50525-1, Annex B
Minimum bending radius  10x cable diameter (flexible) | 4x cable diameter (fixed)
Range of temperature Ambient temperature: -40° C to +90°C; Maximum conductor temperature: +120° C
Order No. No. of cores
in mm2
Construction n x max-Ø (mm) Resistance of
conductor (Ω/km)
External diameter
approx (± 0.2 mm)
Copper index kg/km Weight
~ kg/km
black red             
73 90 65 73 90 66 1 x 1.5 29 x 0.25 13.7 4.6 14.0 32.0
73 86 09 73 86 10 1 x 2.5 47 x 0.25 8.21 5.0 24.0 42.0
73 86 13 73 86 14 1 x 4.0 52 x 0.3 5.09 5.4 38.4 57.0
73 86 15 73 86 16 1 x 6.0 78 x 0.3 3.39 6.0 57.6 76.0
73 86 17 73 86 18 1 x 10.0 77 x 0.4 1.95 7.2 96.0 119.0
73 86 19   1 x 16.0 126 x 0.4 1.24 9.3 153.6 196.0
73 90 61   1 x 25.0 190 x 0.4 0.795 11.3 240.0 291.0
73 90 63   1 x 35.0 266 x 0.4 0.565 12.9 336.0 394.0

 

           

HIKRA® PLUS EN50618 (H1Z2Z2-K)

Your benefits:
  • Because of its excellent insulation material, the cable is particularly water repellent and can be laid directly underground. UL2566 (internal examination) Long-term insulation resistance test in water bath at 90°C >3GΩ*m (internal examination)
  • Nominal voltage: 1,5kV DC and 1,0 kV AC
  • Maximum permitted operating voltage: 1,8kV DC (Internal examination: 2,0kV DC)
  • Short-circuit-temperature: 250° C/5s
  • Reinforced cable sheath: Impact-Resistance UL 854.23 and Crushing-Resistance UL 854.24 (internal examination)
  • UV stability: Tensile strength and ultimate-elongation after 720 h (360 cycles) ≥ 70% of initial values; EN 50289-4-17 acc. method A; EN ISO 4892-1 (2000) and EN ISO 4892-2 (2006)
  • CPR-classification of burning behavior: Eca Declaration of Performance DoP 0743
Order No. No. of cores
in mm2
Construction
n x max-Ø (mm)
Resistance of conductor (Ω/km) External diameter
approx (± 0.2 mm)
Copper quantity kg/km Weight
~ kg/km
black red blue            
72 83 79 72 83 80 72 83 81 1 x 2.5 50 x 0.26 8.21 5.0 24.0 45.0
72 83 70 72 83 71 72 83 72 1 x 4.0 56 x 0.31 5.09 5.4 38.4 55.0
72 83 73 72 83 74 72 83 75 1 x 6.0 80 x 0.31 3.39 6.0 57.6 75.0
72 83 76 72 83 77 72 83 78 1 x 10.0 80 x 0.41 1.95 7.1 96.0 115.0
73 78 60     1 x 16.0 120 x 0.41 1.24 8.1 153.6 170.0
73 78 63     1 x 25.0 196 x 0.41 0.795 10.3 240.0 270.0
73 78 64     1 x 35.0 280 x 0.41 0.565 11.8 336.0 370.0
                 
 

 

           

HIKRA® DUAL 1500V/2000V

The HIKRA® DUAL solar cable is TÜV (EN50618) and UL (UL 4703 PV Wire) certified and thus covers the whole bandwith required for global distribution. Ideal in combination with preassembled cables for manufacturers of junction boxes and modules.

Order No. No. of cores
in mm2
Construction n x max-Ø (mm) Resistance of conductor (Ω/km) External diameter
approx. (± 0.2 mm)
Copper index
kg/km
Weight
~ kg/km
72 78 41 1 x 2.5 / AWG 14 47 x 0.25 8.21 5.94 24.0 49.0
74 06 74 1 x 4.0 / AWG 12 52 x 0.3 5.09 6.35 38.4 64.0
74 06 75 1 x 6.0 / AWG 10 78 x 0.3 3.39 6.97 57.6 84.0
74 11 97 1 x 10.0 / AWG 8 77 x 0.4 1.95 8.57 96.0 137.0

FURTHER HISKON® CABLES

HIKRA® Marten Resistant Cable

with a steel braid of V2A

HIKRA® AC Solar 3P

for use in systems with micro inverters

Underground Cable NYY / NAYY

for cabling the AC or DC side of your system

Data Cable Li2YCYv